in situ

Gamma radiation proportional counters (IRSN/Teleray)

Two probes from the TELERAY network are installed at PDM and CRA stations. Every 10 minutes, these detectors measure the ambient gamma equivalent dose rate in the environment near the probe. Currently these probes are equipped with proportional counters allowing very good measurement sensitivity. Each of these measurements is transmitted in real time to the […]

In situ cloud detection by webcam

Images from a webcam installed by OMP at PDM are used to detect in situ cloudy conditions at the Pic du Midi. The image processing algorithm is based on edge detection using a Canny filter on several areas of the image. Areas with sharp contours will be considered free of cloud, while blurred contours will […]

Radon detector

Radon (222Rn) is a naturally occurring radioactive gas originating exclusively from the earth’s surface, with a source function typically 2–3 orders of magnitude greater from land surface than from ocean. Since it is unreactive and poorly soluble, the sole sink of atmospheric radon is radioactive decay. With its half-life of 3.8 days, radon does not […]

Weekly high-volume sampling of atmospheric radionuclides

https://www.irsn.fr/actualites/episode-sables-sahariens-sur-france-fevrier-2021#.YEn5AehKiUk

Atmospheric Mercury Speciation

This well-known commercial Hg speciation system is installed indoors at the Pic du Midi in order to avoid technical issues during the harsh winter period (ice riming and storms). The system operationally separates 3 different atmospheric Hg species : gaseous elemental Hg (GEM), gaseous oxidized Hg (GOM, such as HgCl2, HgB2, HgO), and particulate bound Hg […]

Weekly flask samples

Dans le cadre du programme ICOS, des prélèvements d’air en flacon sont opérés chaque semaine par l’équipe technique du Pic du Midi depuis 2002. Les flacons sont ensuite envoyés au LSCE où leur composition est analysée : CO2 (et isotopes 13C et 18O), CH4, CO, N2O, SF6 et hydrocarbures non-méthaniques.

Greenhouse-gas analyzer

Continuous measurements of carbon dioxide (CO2), carbon monoxide (CO) and methane (CH4) are conducted in the framework of the national RAMCES/ICOS network since May 2014 at Pic du Midi, and April 2019 at CRA. These measurements are made on both sites by means of Picarro G24 analyzers based on cavity ring-down spectroscopy (CRDS). The applied […]

CO analyzer

Une mesure de la fraction molaire en monoxyde de carbone dans l’air ambiant est conduite en continu depuis 2004, notamment dans le cadre du Service d’Observation PAES de l’INSU de 2004 à 2015. Elle repose sur une mesure de photométrie d’absorption dans l’infrarouge. Dans le cadre du programme MOZAIC (mesures aéroportées sur avions de lignes), trois améliorations […]

O3 analyzer

Une mesure de la fraction molaire en ozone dans l’air ambiant est conduite en continu depuis 2001 au Pic du Midi, notamment dans le cadre du Service d’Observation PAES de l’INSU de 2004 à 2015. Elle repose sur une mesure de photométrie d’absorption dans l’UV (analyseur commercial TEI 49i), en suivant le protocole d’assurance qualité définie par […]